Show simple item record

dc.contributor.authorGeerts, Greta
dc.contributor.authorPatel, Zaheed
dc.date.accessioned2014-05-27T14:20:37Z
dc.date.available2014-05-27T14:20:37Z
dc.date.issued2011
dc.identifier.citationGeerts, G.A.V.M. & Patel, Z. (2011). Temperature changes along a dental implant. International Journal of Prosthodontics, 24 (1): 58-68en_US
dc.identifier.issn0893-2174
dc.identifier.urihttp://hdl.handle.net/10566/1089
dc.description.abstractAIMS: The aims of this in vitro study were to analyse temperature changes along the surface of a dental implant and to establish the abutment temperature that could cause the critical 47ºC/1min threshold at implant level. METHODS: Eight thermocouples were attached at 1 mm intervals to an abutment/implant configuration. The model consisted of 2 compartments in a thermostatically controlled environment. The upper compartment represented the oral cavity with the abutment, which was exposed to 20ml of hot water. The temperature at each thermocouple was logged over a period of 10 minutes. A Spearmans Rank correlation test and logistic regression model were used for the statistical analysis of the time/temperature databases and the estimation of the ‘effective dose 50’ for the abutment (95% confidence interval). RESULTS: For 53 test series, the abutment temperature ranged from 52.80ºC to 71.72ºC. There was a positive correlation between the maximum temperature at implant level and the temperature of the abutment. The 47ºC/1min threshold was reached 31 times at the most cervical implant level and decreased in frequency further away from the heat source (14, 6, 3, 1 and 1 times resp.) The ED50 was estimated at 62.3ºC. This means that for an abutment temperature of 62.3ºC there was a 50% chance that 47ºC for 1 minute at implant level would be reached. CONCLUSION: This in vitro study supports the hypothesis that abutment temperature is transmitted to an implant. Although results of in vitro studies should be interpreted with caution, clinicians should be aware of temperature changes along implants and the potential risk associated with it.en_US
dc.language.isoenen_US
dc.publisherQuintessence Publishingen_US
dc.rightsThis is the author final version, copyright Quintessence Publishing.
dc.subjectDental implanten_US
dc.subjectHeat transmissionen_US
dc.subjectBone necrosisen_US
dc.titleTemperature changes along a dental implanten_US
dc.typeArticleen_US
dc.privacy.showsubmitterfalse
dc.status.ispeerreviewedtrue
dc.description.accreditationWeb of Scienceen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record